December 12, 2003

Refer to: HSA-10/CC-69C

Mr. Kaddo Kothmann
President
Road Systems, Incorporated
3616 Howard County Airport Road
Big Spring, Texas  79720

Dear Mr. Kothmann:

In your October 15 letter, you provided copies of a report prepared by the Midwest Roadside Safety Facility (MwRSF) that documented a fifth test that was conducted on your Box-Beam Burster Energy Absorbing Bridge Pier Protection System, hereafter referred to as the BEAT-BP system.  Information on the first four tests that you ran was submitted previously.  Our review of those earlier tests resulted in changes that were incorporated into a final design and verified in the last test.

The BEAT-BP system consists of a modular (trapezoidal) box-beam frame that can be adjusted in length and width to shield median bridge piers that may vary by number, size, and/or spacing.  Its approach ends use an energy-absorbing terminal with breakaway steel posts similar to your previously accepted BEAT-SSCC (refer to Federal Highway Administration ((FHWA)) acceptance letter CC69B) crash cushion.  The two parallel sides of the box-beam frame are connected by angled struts and consist of single and double box beam rail elements mounted on strong steel posts set on 3-foot centers.  The double rail elements are used to provide additional rail stiffness in the vicinity of the pier(s).  Separate cable anchorages are also used inside the framework to limit system damage in an end-on impact.  A minimum offset of eight inches from the back of the posts to a shielded bridge pier is required.  These and other design details can be seen on Enclosures 1 and 2.

Because the end terminal was similar to the BEAT-SSCC except for the spacing of the breakaway steel posts, National Cooperative Highway Research Program (NCHRP) Report 350 test 3-31 was conducted to verify satisfactory crash performance.  In the head-on 100km/h crash, the pickup truck was stopped in approximately 6.5 m and met occupant impact velocity and ridedown acceleration criteria.  No additional tests were conducted on the terminal itself, but test 3-38 was considered necessary to verify performance when the pickup truck impacted the side of the system just in advance of the diagonal strut that connected the parallel sides of the barrier in advance of the bridge piers.  The test also met all evaluation criteria.  The dynamic deflection of the railing was reported to be 311 mm.  The final test was NCHRP Report 350 test 3-21 which is a 25-degree impact into the side of a device at its transition to a stiffer barrier.  The first two tests on the original BEAT-BP design in which the double box-beam rail was set directly against the bridge piers were unsuccessful because of the location and extent of the resultant passenger compartment intrusion and both hood and fender contact with the simulated concrete bridge pier itself.  For the last test, the design shown in the enclosures was tested.  As noted above, the barrier was offset eight inches from the face of the bridge piers.  As noted in the MwRSF August 12, report entitled “Performance Evaluation of the Redesigned BEAT Bridge Pier Protection System”, the occupant impact velocity of 5.84 m/sec and the ridedown acceleration of 11.77 g's were both lower than the Report 350 preferred values of 9 m/sec and 15 g's.  The pickup truck was contained and redirected upright.  However, due to the relative stiffness of the box beam rail and its narrow impact face, there was significant deformation to the passenger compartment.  Maximum vertical deflections of 203 mm and 194 mm were reported near the right-middle section of the driver-side floor pan, and a 191 mm lateral deflection was noted near its left front corner.  Lateral deformations exceeding 150 mm were reported at four additional locations in the driver compartment.  Damage also included a large opening in the seam of the floor pan under the brake pedal.  Because of the location of the deformations, the test was labeled a “marginal pass” by the researchers.

As you know, the location and degree of passenger compartment intrusion likely to cause serious injuries to vehicle occupants is a subjective decision.  Lacking specific guidance, FHWA has set 150 mm of intrusion as the limiting value for most cases, but we have accepted a few individual tests where the intrusion was greater than 150 mm.  The NCHRP Report 350 states that the degree of acceptable intrusion is a factor “that must by assessed…by the judgment of the test agency and the user agency, or both.”  Since the researchers considered the intrusion seen in test 3-21 to be acceptable, I will agree with their conclusion that the BEAT BP system is marginally acceptable and may be used as a test level 3 device on the National Highway System (NHS), provided that it is selected with full user awareness of its observed performance characteristics.

Please note the following standard provisions that apply to this specific letter of acceptance:

Sincerely yours,

                                                                        /Original Signed By/

            John R. Baxter, P.E.
                                                                        Director, Office of Safety Design
                                                                        Office of Safety

2 Enclosures