Refer to: HSSD/LS-64

Mr. Ray Minor
HAPCO
26252 Hillman Highway
Abingdon, VA  24210

Dear Mr. Minor:
Your letter March 20, 2007, requests the Federal Highway Administration (FHWA) to revise our acceptance issued for your company's HAPCO cast base assemblies for decorative lighting poles for use on the National Highway System (NHS) under the provisions of National Cooperative Highway Research Program (NCHRP) Report 350 "Recommended Procedures for the Safety Performance Evaluation of Highway Features."  Accompanying your most recent correspondence was a revised report on testing of your system conducted by the Texas Transportation Institute (TTI).  This letter revises our previous letter, LS-64, to include updated cast base assembly model numbers and includes the consideration of a cast base that was retested and redesigned.


Requirements
Luminaire supports should meet the guidelines contained in the NCHRP Report 350, "Recommended Procedures for the Safety Performance Evaluation of Highway Features".  The FHWA Memorandum “ACTION: Identifying Acceptable Highway Safety Features” of July 25, 1997, provides further guidance on crash testing of luminaire supports and on use of low-speed pendulum tests as a surrogate for full-scale crash testing.

Product description
The following four HAPCO Decorative Lighting Pole Bases were tested at the TTI outdoor pendulum testing facility.

  1. HAPCO A73704 Cast Base Assembly for a Decorative Lighting Pole.  The base of the lighting pole was cast aluminum (alloy 356-T6) with a 11.5 inch (292 mm) square base going into an octagonal shape and then tapering to a fluted base for a base height of 3 ft-7-1/4 inches (1.1 m).  Atop this was a 5 inch (127 mm) diameter straight aluminum tube (Alloy 6063-T6) with
    0.188 inch (4.8 mm) wall thickness and a length of 16 ft-4-3/4  inches (5 m), giving a total height of 20 ft (6.1 m).  A cast aluminum adapter ring was placed on top of the pole to accommodate the round light.  The weight of the pole with base was 86.8 pounds (39.4 kg) and the round light was 23.8 pounds (10.8 kg), totaling a weight of 110.6 pounds (50.2 kg).  The base was attached to a steel reaction plate with 1/2 inch (12.7 mm) steel anchor bolts, hex nuts, lock washers, and flat washers.  Drawings of the HAPCO A73704 cast base assembly and the A88869 test pole are enclosed.

  2. HAPCO A76696 Cast Base Assembly for a Decorative Lighting Pole.  The base of the lighting pole was cast aluminum (alloy 356-T6) with a 17 inch round base (432 mm) tapering to a fluted shape for a base height of 20-1/4 inches (514 mm).  A 5.8 inch (147 mm) diameter tapering to a 3 inch (76 mm) diameter aluminum tube (alloy 6063-T6) with a 0.125 inch (3.2 mm) wall thickness and a length of 18 ft-3-3/4 inches (5.6 m) was welded to the base, giving a total height of 20 ft (6.1 m).  A cast aluminum adapter ring was placed on top of the pole to accommodate the round light.  The weight of the pole with the base was 91.0 pounds (41.3 kg) and the round light was 23.8 pounds (10.8 kg), totaling a weight of 114.8 pounds (52.1 kg).  The base was attached to a steel reaction plate with 3/4 inch (19 mm) steel anchor bolts, hex nuts, lock washers and flat washers.  Drawings of the HAPCO A76696 cast base assembly and the B88870 test pole are enclosed.

  3. HAPCO A79419 Cast Base Assembly for a Decorative Lighting Pole.  The base of the lighting pole was cast aluminum (alloy 356-T6) with a 17 inch round base (432 mm) tapering to a fluted shape for a base height of 30-3/4 inches (0.78 m).  A 6 inch (152 mm) diameter tapering to
    3 inch (76 mm) diameter aluminum tube (alloy 6063-T6) with 0.188 inch (4.8 mm) wall thickness and a length of 17 ft-5-1/4 inches (5.3 m) was welded to the base, giving a total height of 20 ft (6.1 m).  A cast aluminum adapter ring was placed on top of the pole to accommodate the round light.  The weight of the pole with base was 110.2 pounds (50 kg) and the round light was 23.8 pounds (10.8 kg), totaling a weight of 134.0 pounds (60.8 kg).  The base was attached to a steel reaction plate with 3/4 inch (19 mm) steel anchor bolts, hex nuts, lock washers and flat washers.  Drawings of the HAPCO A79419 cast base assembly and the A88871 test pole are enclosed.

  4. HAPCO A78284 Cast Base Assembly for a Decorative Lighting Pole.  The base of the lighting pole was cast aluminum (alloy 356-T6) with an octagonal base going into a fluted tube for a base height of 42 inches (1.1 m).  Atop this was a 5 inch (127 mm) aluminum tube (alloy 6063-T6) with 0.188 inch (4.8 mm) wall thickness and 16 ft-6 inches long (5 m), giving a total height of
    20 ft (6.1 m).  A cast aluminum adapter ring was placed on top of the pole to accommodate the square light.  The weight of the pole with base was 103.2 pounds (46.8 kg) and the round light was 15.0 pounds (6.8 kg), totaling a weight of 118.2 pounds (53.6 kg).  The base was attached to an in-ground 5 inch (127 mm) diameter aluminum tube (alloy 6063-T6) with 0.188 inch
    (4.8 mm) wall thickness, 4 ft (1.22 m) long, and flattened 12 inches (305 mm) from the bottom with a 2.5 inch (63.5 mm) wide by 8 inch (203 mm) long slotted hole centered 2 ft (0.61 m) below the ground surface.  Drawings of the HAPCO A78284 cast base assembly and the A88868 test pole are enclosed.

Testing
Your company’s cast base assemblies for decorative lighting poles were tested at the TTI outdoor pendulum testing facility, as a surrogate for full-scale crash testing.  The pendulum bogie was built according the specifications of the Federal Outdoor Impact Laboratory's (FOIL)

pendulum, and the frontal crush of the aluminum honeycomb nose of the bogie simulated the crush of an actual vehicle.  Tests with pendulums are acceptable for most breakaway supports, exceptions being base bending or yielding supports.

Five low speed pendulum tests were conducted on your company’s assembly bases for decorative lighting poles, one test on each of the poles with an additional test conducted on HAPCO A79419.  Summaries of the test results are provided in Enclosure 2.  All of the cast base assemblies met the NCHRP Report 350 occupant risk criteria.  In addition, TTI extrapolated the high-speed performance from the low speed pendulum tests.  We agree that the test articles appear to perform appropriately to make such high-speed extrapolations.  All high speed extrapolations yield lower change in velocity values than the paired low speed pendulum tests.

In tests with HAPCO A73704 and HAPCO A76696 cast base assemblies, the base pulled out of the anchor bolts.  In the test with HAPCO A78284 cast base assembly, the base fractured at ground level.  This performance satisfies the FHWA limit of maximum 4 inch (100 mm) stub height remaining after a support breaks away.

However, in the first test conducted on the HAPCO A79419 cast base assembly, the remaining base left on the reaction plate was 9 inches (229 mm) tall, which exceeds the FHWA limit of a maximum 4 inch (100 mm) stub height.  While you reported that a portion of the fractured base was contacted by the pendulum sweeper plate and the associated change in velocity was negligible, a concern remained that the stub may have a potential to cause vehicle undercarriage snagging and vehicle instability if a wheel hits the stub.  The same cast base assembly was retested and the base fractured at ground level.  The cast base appears to fracture randomly when impacted, and the FHWA requested additional changes be made to the design.  Subsequently, the HAPCO A79419 cast base assembly was redesigned as shown on HAPCO Drawing A12500 (enclosed) to match the HAPCO A76696 by widening the anchor bolt slots.  With the passing test and subsequent design improvement, the HAPCO A12500 is now acceptable to the FHWA and no further testing is required.

In summary, we agree that HAPCO A73704, HAPCO A76696, HAPCO A12500, and HAPCO A78284 cast base assemblies for decorative lighting poles as described above, meet the appropriate evaluation criteria for a NCHRP 350 Test Level 3 devices and may be used at all appropriate locations on the NHS when selected by the contracting authority, subject to the provisions of Title 23, Code of Federal Regulations, Section 635.411 as they pertain to proprietary products.