Skip to contentSkip to contentUnited States Department of Transportation - Federal Highway Administration FHWA HomeFeedback


DOT logo
U.S. Department of Transportation

Federal Highway Administration

400 Seventh St., S.W.
Washington, D.C. 20590

September 5, 2008

In Reply Refer To:
HSSD/SS-126 (REVISED)

Mr. Raymond Kisiel
Northwest Pipe Company
6307 Toledo Street
P.O. Box 2002
Houston, TX 77252-2002

Dear Mr. Kisiel:

Thank you for your letter of October 27, 2004, requesting the Federal Highway Administration’s (FHWA) acceptance of your company’s perforated square steel tubes as breakaway sign supports for use on the National Highway System (NHS). Accompanying your letter was a report from the Texas Transportation Institute and videos of the crash tests. You requested that we find your company’s soil-mounted posts acceptable for use on the NHS under the provisions of the National Cooperative Highway Research Program (NCHRP) Report 350 “Recommended Procedures for the Safety Performance Evaluation of Highway Features.”

Introduction
Testing of the supports was in compliance with the guidelines contained in the NCHRP Report 350, Recommended Procedures for the Safety Performance Evaluation of Highway Features. Requirements for breakaway supports are those in the American Association of State Highway and Transportation Officials' (AASHTO) Standard Specifications for Structural Supports for Highway Signs, Luminaires and Traffic Signals.

A combination of full-scale automobile and bogie pendulum testing was conducted on your company’s devices. The mass of the test vehicle was 866 kg, and the mass of the pendulum bogie was 820 kg. Although pendulum tests are not routinely accepted for use with base-bending/yielding supports, the crash behavior and post-impact vehicle trajectory is fairly well known for perforated square steel posts. The FHWA concurred in the use of pendulum testing to verify performance for your company’s posts as a new manufacturer.

All supports tested were ASTM A653, G90, Structural Quality Grade 50 steel perforated square steel tubes inserted into an anchor that was one size larger than the sign post. The tests are summarized below. The complete devices as tested are shown in the Enclosures.

400001-NWP1 Full scale automobile test. Dual post. Two 2-1/2 inch 12-gage posts inserted 10 inches into 36 inch long anchors, spaced 36 inches on center. The posts were secured to the anchors with 3/8 inch corner bolts. A 48 x 72 inch by 5/8 inch thick plywood sign panel was attached to the posts with 0.375 inch, 3.5 inch long bolts. The bottom of the sign was mounted 84 inches above the ground. The tops of the anchors were one inch above the ground. Upon impact the posts bent and the sign impacted the roof. The anchors and posts pulled out of the weak soil and the sign panel separated from the posts. Windshield damage was minimal to moderate, with cracking in both layers of glass. No holes were made through all three layers of the windshield.

400001-NWP5 Pendulum test. Single post. One 2-1/2 inch 12-gage post was inserted 10 inches into a 36-inch long, 3 x 3 inch square 7-gage anchor embedded 35 inches into Report 350 Standard soil. A 36 x 43 inch by 5/8 inch thick plywood sign panel was attached to the post at a height of 7 feet to the bottom. The posts were secured to the anchors with 3/8 inch corner bolts.

400001-NWP6 Pendulum test. Single Post. Same as above except the installation was in weak soil, and the anchor was winged.

Test # NCHRP 350 Speed Version Article Occup. Speed Delta V
1 3-61, Weak 99.2 km/h Dual 2 inch 12 ga Gr 50 3.6 m/s 3.6 m/s
2 3-61, Standard 35 km/h Single 2.5 in 12 ga Gr 50 None 3.3 m/s
3 3-61, Weak 35 km/h Single 2.5 in With anchor None 2.4 m/s

NCHRP 350: Report 350 test designation, and soil type.
Version: Number of posts struck and size of each
Article: Thickness of post and grade of steel
Occup. Speed: Occupant Impact Speed.
Delta V: Speed change of the test vehicle, in meters per second.

Findings
Damage in test 1 was limited to cracking of the windshield and bumper damage. Sign trajectory in all 3 tests was satisfactory. Velocity changes were all within acceptable limits, and the only stub remaining was in test 2 where the post was pulled partially up out of the ground. The results of testing met the FHWA requirements and, therefore, the devices described above and shown in the enclosed drawings for reference are acceptable for use as Test Level 3 devices on the NHS under the range of conditions tested, when proposed by a State.

Your company’s Pickperf ™ square steel tube supports are also accepted and considered equivalent for the sizes requested that include the square 1.75 inch and the 2 inch, 14 gauge sign supports. The Pickperf ™ supports’ specifications are similar to Northwest Pipe Company’s tested and accepted square steel tube supports.

Additionally, you submitted certification of the steel coil material that specifies the mechanical properties of the steel used to produce the tube. The tensile strength did not exceed 79,800 psi and the percent elongation when measured over 2 inches must not exceed 28 percent. Due to the properties of the materials tested as mentioned above and shown in the submitted steel coil material certifications, we have revised the footnotes and produced a table that describes the sizes, foundation conditions, and number of supports that may be used. The enclosed table, “Acceptable Uses of Perforated Square Steel Tube Sign Posts, Per Request of Northwest Pipe Company,” delineates the sizes, foundation conditions, and number of supports that may be used.

Please note the following standard provisions that apply to the FHWA letters of acceptance:

Sincerely yours,

Signature of George E. Rice, Jr.

George E. Rice, Jr.
Acting Director, Office of Safety Design
Office of Safety                                          

Enclosure

Acceptable Uses of Perforated Square Steel Tube Sign Posts, Per request of Northwest Pipe Company

Posts are fabricated from ASTM A653 SQ Grade 50, Modified to "Grade 55", certified to 414 MPa min yield1

Post Size
mm x mm (in x in)
One Post in a 2.1-m Path Two Posts in a 2.1-m Path
Standard Soil Weak Soil Standard Soil Weak Soil
With
Anchor
Base(2)
Direct
Burial
With
Anchor
Base(2)
Direct
Burial
With
Anchor
Base(2)
Direct
Burial
With
Anchor
Base(2)
Direct
Burial
2.10
mm
2.66
mm
2.10
mm
2.66
mm
2.10
mm
2.66
mm
2.10
mm
2.66
mm
2.10
mm
2.66
mm
2.10
mm
2.66
mm
2.10
mm
2.66
mm
2.10
mm
2.66
mm
63.5x63.5 (2.5x2.5) yes yes
57.2x57.2 (2.25x2.25) yes yes yes yes yes yes yes yes
50.8x50.8 (2.0x2.0) yes yes yes yes yes yes yes yes yes yes yes yes yes yes
44.5x44.5 (1.75x1.75) yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes
38.1x38.1 (1.5x1.5) yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes
  1. 413.69 MPa = 60,000 psi. The ultimate tensile strength of the steel coil used to produce the tube should not exceed 550 MPa (79,800 psi) or have an elongation measured over 50 mm (2 inches) greater than 28%.
  2. The anchor base may or may not have a strengthening sleeve at groundline. The anchor bases shall be sized to fit closely around the post. For 63.5x63.5 posts of both wall thicknesses and 57.2x57.2x2.66 posts the anchor bases shall be made of steel comparable to that of the posts and have wall thicknesses equal 4.55 mm (7 ga) or greater. For 57.2x57.2x2.10 posts and all 55.6x55.6 and smaller posts the anchor bases shall be made of steel comparable to that of the posts and have wall thicknesses equal 2.66 mm (12 ga) or greater.

Safety Home | FHWA Home | Feedback