Refer to: HSA-10/WZ-100

Mr. Bill Korman
Korman Signs, Incorporated
3029 Lincoln Avenue
Richmond, Virginia  23228

Dear Mr. Korman:

Thank you for your letter of May 23, 2002, requesting Federal Highway Administration (FHWA) acceptance of a number of your company's portable sign stands as crashworthy traffic control devices for use in work zones on the National Highway System (NHS).  Accompanying your letter were reports of crash testing conducted by General Testing Services and video of the tests.  You requested that we find these devices acceptable for use on the NHS under the provisions of National Cooperative Highway Research Program (NCHRP) Report 350 “Recommended Procedures for the Safety Performance Evaluation of Highway Features.”  On June 13, 2002, you met with Mr. Artimovich of my office and provided information in addition to that in the original request.

Introduction

The FHWA guidance on crash testing of work zone traffic control devices is contained in two memoranda.  The first, dated July 25, 1997, titled “INFORMATION: Identifying Acceptable Highway Safety Features,” established four categories of work zone devices: Category I devices were those lightweight devices which could be self-certified by the vendor, Category II devices were other lightweight devices which needed individual crash testing, Category III devices were barriers and other fixed or massive devices also needing crash testing, and Category IV devices were trailer mounted lighted signs, arrow panels, etc. The second guidance memorandum was issued on August 28, 1998, and is titled "INFORMATION: Crash Tested Work Zone Traffic Control Devices.” This later memorandum lists devices that are acceptable under Categories I, II, and III.

A brief description of your requests, including designation of the sign stands and the sizes and substrates you wish to use follows:

Request Number 1:      

Stands:
SS560, SS560A, SS560E, SS560AE

Signs:
60x60 or smaller Diamond or Square
48x60 or smaller Rectangle       

Substrates:
0.100, and .080 Al., 5/8 or ˝ Plywood, 6.35mm SP, Endurance, HDPE, 10mm CP, Alpolic, Roll Up, 3-4mm ACS

Other
With or without 48x30 or smaller supplementary panel using 10mm CP, Alpolic, or Roll Up
With or without flags, light or ballast

Mounting Ht:
60 inches for diamond, 63 inches for rectangle, 21 inches for supplemental

Request Number 2:      

Stands:
SS548, SS548A, SS548E, SS548AE, SS548C, SS548CE, SS548CA, SS548CAE

Signs:
48x60 or smaller Rectangle

Substrates:
Alpolic, 10mm CP,  Roll Up

Other:
With or without flags, lights, or ballast

Mounting Ht:
21 inches

Request Number 3:      

Stands:
SS548E, SS548AE, SS548CE, SS548CAE

Signs:
60x60 or smaller Diamond or Square
48x60 or smaller Rectangle

Substrate:
Roll Up

Other:
With or without 48x30 or smaller supplementary panel using 10 mm CP, Alpolic, or Roll Up
With or without flags, or ballast

Mounting Ht:
48 to 60 inches for diamond or rectangle, 21 inches for supplemental sign

Request Number 4:      

Stands:
Type III Barricade

Signs:
60x60 or smaller Diamond or Square
60x48 or smaller Rectangle
25 Square Foot or smaller combination of signs

Substrate:
Alpolic

Other:
With or without ballast

Mounting Ht:
N/A

Request Number 5:      

Stand:
SS1     

Signs:
48x48 or smaller Diamond or Square
48x60 or smaller Rectangle

Substrates:
.100 and .080 Al., 5/8 and 1/2 Plywood, Endurance, 6.35mm SP, HDPE,
10mm CP, Alpolic, Roll Up, 3-4mm ACS

Other:
With or without flags, or ballast

Mounting Ht:
13 to 14 Inches for diamond, 24 inches for rigid rectangle
13 to 28 inches for roll-up rectangle for 48x60 and 48x24 inch signs

Request Number 6:      

None:
Deleted from original request. Repeated elsewhere in this submittal

Request Number 7:      

Stands:
SS548, SS548AE, SS548CE, SS548CAE

Signs:
60x60 or smaller Diamond or Square
48x60 or smaller Rectangle

Substrates:
10mm CP, Alpolic, Roll Up

Other:
With or without flags, light, or ballast

Mounting Ht:
19 to 21 inches

Request Number 8:      

Stands:
SS548, SS548A, SS548C, SS548CA

Signs:
60x60 or small Diamond or Square

Substrate:
Roll Up

Other:
With or without flags, or ballast

Mounting Ht:
19 to 21 Inches

Request Number 9:     

Stands:
SS548UC, SS548UCA, SS548UCX, SS548UCAX

Signs:
60x60 or smaller Diamond or Square
48x60 or smaller Rectangle

Substrate:
Roll Up

Other:
With or without flags, or ballast

Mounting Ht:
21 Inches

Request Number 10:    

Stands:
SS560UC, SS560UCA, SS560UCX, SS560UCAX

Signs:
60x60 or smaller Diamond or Square
48x60 or smaller Rectangle

Substrate:
Roll Up

Other:
With or without flags, or ballast

Mounting Ht:
60 Inches

Request Number 11:    

Stands:
SS548UCR, SS548UCRA, SS560UCR, SS560UCRA, SS548UCRX, SS548UCRAX, SS560UCRX, SS560UCRAX

Signs:
60x60 or smaller Diamond or Square
48x60 or smaller Rectangle

Substrate:
Roll Up

Other:
With or without flags, or ballast

Mounting Ht:
13 Inches

Request Number 12:    

Stands:
SS548, SS548E, SS548A, SS548AE, SS548C, SS548CE, SS548CA, SS548CAE

Signs:
48x48 or smaller Diamond or Square
48x60 or smaller Rectangle

Substrates:
.080 Al, Endurance, 6.35mm SP, 10mm CP, HDPE, Alpolic, 3-4mm ACS

Other:
With or without flags, light, or ballast

Mounting Ht
19 Inches

Abbreviations used in the above requests are:

Al.:  Solid aluminum substrate
SP: Solid plastic (ABS) substrate
CP: Corrugated plastic
HDPE: Hollow core blow molded high density polyethylene waffle pattern substrate
Alpolic: 2 mm aluminum laminate composite substrate
ACS: Aluminum composite substrate/aluminum laminate 3 or 4 mm thick.

Enclosure #1 is a summary of the acceptances that this request embraces, with an indication of the mounting height of each sign that was tested and is to be considered for acceptance.

Testing

Full-scale automobile testing was conducted on your company's devices.  Generally, two stand-alone examples of the device were tested in tandem, one head-on and the next placed six meters downstream turned at 90 degrees, as called for in our guidance memoranda.  In some cases, different combinations of sign sizes and/or substrates were used on the two stands tested in order to qualify a broader range of hardware.  The “worst case scenario” tests for the head-on and 90-degree impacts were discussed in advance with Mr. Artimovich.  Enclosure #2 is a summary of the 37 crash tests conducted to support the requests.  Enclosure #3 is another summary which relates the individual stands to the tests conducted as part of this submission, as well as to earlier FHWA letters of acceptance which support the individual request.  Enclosure #4 is a summary of the product description and a glossary of terms used to describe the variations in your company's stands.  Enclosure #5 contains a drawing of each stand, for reference.

Findings

Damage was limited to moderate cracking of the windshield in a number of tests, as noted in Enclosure #2, plus various damage to the bumper, hood, and roof of the test vehicles.  There were no instances of passenger compartment penetration or intrusion.

 The results of the testing met the FHWA requirements and, therefore, the devices described in the various requests above and detailed in the enclosed tables and drawings are acceptable for use on the NHS under the range of conditions tested, when proposed by a State.

Please note the following standard provisions that apply to FHWA letters of acceptance:

Sincerely yours,

Carol H. Jacoby, P.E.

Director, Office of Safety Design

Enclosure