Refer to: HSA-10/WZ-107

Mr. Leo J. Yodock, III
Yodock Wall Co., Inc.
Ft. Lauderdale, FL  33315           

Dear Mr. Yodock:

Thank you for your letters of September 4, 2001, requesting Federal Highway Administration (FHWA) acceptance of your company's Energy Dispersement Cell Barricade (EDCB) as a crashworthy traffic control device for use in work zones on the National Highway System (NHS).  Accompanying your letter was a report of crash testing conducted by the Texas Transportation Institute and videos of the tests. You requested that we find this device acceptable as a Test Level 3 (TL-3) devices, respectively, for use on the NHS under the provisions of   National Cooperative Highway Research Program (NCHRP) Report 350 “Recommended Procedures for the Safety Performance Evaluation of Highway Features.”

On December 13, 2001, you met with members of the Office of Safety Design staff to discuss the crash-testing program, the results, and the proposed uses associated with these devices.  On January 9, 2002, you submitted additional information as discussed at our meeting.

Introduction

The FHWA guidance on crash testing of work zone traffic control devices is contained in two memoranda.  The first, dated July 25, 1997, titled “INFORMATION: Identifying Acceptable Highway Safety Features,” established four categories of work zone devices: Category I devices were those lightweight devices which could be self-certified by the vendor, Category II devices were other lightweight devices which needed individual crash testing, Category III devices were barriers and other fixed or massive devices also needing crash testing, and Category IV devices were trailer mounted lighted signs, arrow panels, etc.  The second guidance memorandum was issued on August 28, 1998, and is titled “INFORMATION: Crash Tested Work Zone Traffic Control Devices.”  This later memorandum lists devices that are acceptable under Categories I, II, and III.

A brief description of the device follows:

Energy Dispersement Cell Barricade - TL-3

The Yodock Barrier Model 2001 EDCB units are rotomolded, low-density polyethylene, water-filled containers.  Overall dimensions on these units are 1830 mm long, 1170 mm tall, 610 mm width at the base, and 280 mm wide at the top.  There are two forklift holes at 530 mm above ground level that nominally measure 150 mm x 280 mm. The bottom vertical face of the device is 230 mm in height.  For this test, water ballast was placed in the units to the maximum capacity.  The approximate full mass of each unit is 1025 kg (1650 pounds.)  A total of three units were placed adjacent to each other and coupled with Polyethylene couplers.  The total length of the installation was 5.5 m (18 ft.)

The Type III barricade atop each water filled unit was fabricated with two 50 mm (2 inch) schedule 80 PVC pipes, 2.59 m long (102 inch) supports.  The center of the support pipes are placed 330 mm (13 in) from each end of the units.  Hollow plastic lumber measuring 20 mm (3/4 inch) thick, 195 mm (7.7 inches) tall, by 1840 mm (72.4 inches) long was attached to the PVC pipe with 6 mm (1/4 inch) “U” bolts.  The top of the middle horizontal panel was 1940 mm (76.4 inches) above the ground.  The top of the upper horizontal panel was mounted 2440 mm (96 inches) above grade. In addition, a 1220 mm x 1220 mm x 12 mm (4 foot x 4 foot x 7/6 inch) plywood sign panel was bolted to the middle Type III barricade.  The top of the sign panel was 3250 mm (128 inches) above grade.  Four battery powered warning lights were attached to the top of the pipe supports.

This device was evaluated as a road-closure system to be placed perpendicular to the centerline of the roadway.  A similar Yodock system was successfully crash tested earlier and accepted by FHWA Acceptance Letter WZ-34 dated March 23, 2000.  It consisted of a single unit with type III apparatus with no water ballast added.  Because the vehicle velocity change for that device was 3.9 m/s it was known that an impact into a similar barricade system filled with water would cause unacceptable decelerations.  It was decided to run such a test anyway to determine the worst possible performance of this system.  One reason for this ultimate test was the proposed use for such a system: it is intended to be placed at right angles to the roadway to deter vehicles from proceeding beyond that point.  It was expected that the water-filled barricade would keep vehicles from filtering through, be very difficult for unauthorized persons to move, yet still be somewhat forgiving in the event of a crash.  Please note that, as a result of this testing, it has been determined that these units may not be completely filled with water when deployed.

For this device, a single Report 350 test 3-71 was conducted with an 820 kg passenger car impacting the center barricade of the array head-on at a speed of 100 km/hr.

Testing                                                           

Full-scale automobile testing was conducted on your company's devices.  The test results are summarized in the following table.

Test Number

400001-YWC2

NCHRP Report 350 Test #

3-71

Test Article

Type III Barricade

Height to Bottom of Sign

1535 mm

Height to Top of Sign

3260 mm

Flags or lights

4 Type A/C Beacons

Test Article Mass (one cell)

1056 kg

Vehicle Inertial Mass

820 kg

Impact Speed

96.3 km/hr

Occupant Risk Values:

  Occupant Impact Velocity

8.5 m/s

  Ridedown x-direction

-2.0 g's

  Ridedown y-direction

2.0 g's

  Max 0.050-s accel x-dir

-16.2 g's

  Max 0.050-s accel y-dir

-1.4 g's

  Max 0.050-s accel z-dir

-3.2 g's

Vehicle crush

280 mm max

Occupant Compartment Intrusion

95 mm (crush)

Windshield Damage

Hole caused by hood

The mass of the middle cell was 60 kg (cell unit) +  965 kg (water) + 20 kg (barricade posts and panels) + 11 kg (sign on middle cell only)

In the EDCB test, the vehicle broke through the middle barricade, pulling those to the right and to the left along with it for a short distance.  The impact forced the hood back into the windshield, causing a hole in the glass.  Even though the test resulted in a hole in the windshield, parts of the device itself did not show potential for penetrating the occupant compartment. Because of the mass of the water in the filled cells, Occupant Impact Velocity exceeded that for a breakaway work zone traffic control device.  However, it was within the desirable limit for a crash cushion impact and is considered survivable.

Findings                                             

The Model 2001 Type III EDCB tested full of water, exceeded the velocity change requirements for a work zone traffic control device.  However, its intended use is to hinder access to an area and be difficult to move.  The researchers calculated that the occupant impact velocity of 5 meters per second would not be exceeded if the volume of water was reduced by half in these units.  Therefore, we conclude that the Model 2001 Type III barricade will be acceptable for road closures in if the cell units are used half filled with water (482 kg of water).   The fill mark or other method of regulating the maximum water line must be permanently incorporated into the EDCB units.  An additional condition is that they not be placed in a location where traffic running perpendicular to the closed road cannot impact the end of a EDCB installation as they have not been crash tested at the 90 degree orientation.

Because this device has been tested and met the unique requirements that had been set for them, the device described above and shown in the enclosed drawings for reference is acceptable for use on the NHS under the range of conditions tested and the additional conditions discussed above, when proposed by a State.  In addition, the Model 2001m EDCB, the base unit of which is 812 mm tall, will also be acceptable subject to the same conditions and restrictions as the crash-tested Model 2001 EDCB.

Please note the following standard provisions that apply to FHWA letters of acceptance:

Sincerely yours,

Michael L. Halladay

Acting Program Manager, Safety