Skip to contentSkip to contentUnited States Department of Transportation - Federal Highway Administration FHWA HomeFeedback


DOT logo
U.S. Department of Transportation

Federal Highway Administration

400 Seventh St., S.W.
Washington, D.C. 20590

 

February 25, 2005

Refer to: HSA-10/WZ-196

Mr. Chuck Mettler
Plastic Safety Systems
444 Baldwin Road
Cleveland, Ohio 44104

Dear Mr. Mettler:

Thank you for your letter of December 8, 2004, requesting Federal Highway Administration (FHWA) acceptance of up to 25 square feet of lightweight signs to your company's 8 foot wide and smaller Type III barricades as crashworthy traffic control devices for use in work zones on the National Highway System (NHS). You requested that we find these devices acceptable for use on the NHS under the provisions of the National Cooperative Highway Research Program (NCHRP) Report 350 "Recommended Procedures for the Safety Performance Evaluation of Highway Features."

Introduction

The FHWA guidance on crash testing of work zone traffic control devices is contained in two memoranda. The first, dated July 25, 1997, titled "INFORMATION: Identifying Acceptable Highway Safety Features," established four categories of work zone devices: Category I devices are those lightweight devices which are to be self-certified by the vendor, Category II devices are other lightweight devices which need individual crash testing but with reduced instrumentation, Category III devices are barriers and other fixed or heavy devices also needing crash testing with normal instrumentation, and Category IV devices are trailer mounted lighted signs, arrow panels, etc. for which crash testing requirements have not yet been established. The second guidance memorandum was issued on August 28, 1998, and is titled "INFORMATION: Crash Tested Work Zone Traffic Control Devices." This later memorandum lists devices that are acceptable under Categories I, II, and III.

Plastic Safety Systems Type III Barricade

The horizontal rails, or "legs," are 1217-mm (48 inch) long, 98 mm (3.9 inch) square High Density Polyethylene (HDPE), and are placed 1225 mm (48 inches) apart. Underneath each end of the legs rubber pads are attached to increase friction with the pavement. On the top center of each leg is bolted a 127 mm x 76 mm (5 x 3 inch) steel plate, to which is welded a 72 mm diameter x 3.06 mm wall x 200 mm (2.83 x 0.12 x 7.87 inch) long steel tube. These steel tubes support the vertical upright masts, which are 88 mm (3.5 inch) square x 5.08 mm (0.2 inch) wall x 1521 mm (60 inch) long HDPE plastic. To these vertical masts are bolted (with 1/4 - 20 bolts and nuts with washers) three 205 mm (8 inch) wide x 22.75 mm (0.9 inch) thick x 2435 mm (8 feet) long HDPE honeycomb extrusions. A "ballast board" was also used to connect the legs. This 130 mm (5 inch) wide x 29.83 mm (1.2 inch) thick x 1225 mm (48 inch) long HDPE extrusion with a wall thickness of 6.1 mm (1/4 inch) was installed as a safer location to place sandbags.

This configuration was tested in accordance with the NCHRP Report 350 guidelines and was successful. Subsequent informal testing of the Type III barricade with the ANCHOR base system showed that it was an acceptable alternative to the square HDPE leg. This was acknowledged in the FHWA acceptance letter WZ-152 dated April 10, 2003.

Discussion and Findings

Your present request is to permit modifications to your Type III plastic barricade by adding up to 25 square feet of lightweight substrate signs. Lightweight substrates were defined in the FHWA acceptance letter WZ-85 dated November 15, 2001. Minimum mounting height is 12 inches above the roadway, and all signs will be mounted directly to the rails. The FHWA acceptance letter WZ-100, dated June 20, 2002, permits up to 25 square feet of aluminum laminate substrate material to be used on any NCHRP Report 350 accepted Type III barricade. As corrugated plastic sign substrates up to 10 mm thickness, can be expected to perform in a similar manner when bolted to Type III Barricades using 5/16 inch fasteners, we find their use acceptable on the NHS under the range of conditions originally tested, when proposed by a State. This finding applies to your Type III Barricades, up to 8 feet in width, as found acceptable in the following letters:

WZ-61 dated December 13, 2000
WZ-102 dated April 12, 2002
WZ-152 dated April 10, 2003
WZ-166 dated November 12, 2003
WZ-190 dated August 11, 2004

Please note the following standard provisions that apply to the FHWA letters of acceptance:

Sincerely yours,

/Original Signed by Harry W. Taylor/
~for~

John R. Baxter, P.E.
Director, Office of Safety Design
Office of Safety


Safety Home | FHWA Home | Feedback