March 29, 2011

In Reply Refer To:
HSST/B-218

Mr. Paul Fossier, P.E.
Assistant Bridge Design Administrator
Louisiana Department of Transportation and Development
Bridge and Structural Design Section, Rm. 608J
Baton Rouge, LA 70804-9245

Dear Mr. Fossier:

This letter is in response to your request for Federal Highway Administration (FHWA) acceptance of a roadside safety system for use on the National Highway System (NHS).

Name of system: F-Shape Reinforced Concrete Barrier with Slotted Drain Holes
Type of system: Permanent F-Shape Reinforced Concrete Barrier
Test Level: National Cooperative Highway Research Program (NCHRP) Report 350 Test Level 4 (TL-4)
Testing conducted by: Texas Transportation Institute (TTI)
Date of request: December 9, 2010
Task Force 13 Designator: SBC04d

You requested that we find this system acceptable for use on the NHS under the provisions of the NCHRP Report 350 “Recommended Procedures for the Safety Performance Evaluation of Highway Features.”

Requirements
Roadside safety systems should meet the guidelines contained in the NCHRP Report 350. FHWA memorandum “ACTION: Identifying Acceptable Highway Safety Features” of July 25, 1997, provides further guidance on crash testing requirements of longitudinal barriers.

Decision
The following device was found acceptable, with details provided below:

Description
The Louisiana Department of Transportation and Development (La DOTD) currently uses a cast-in-place concrete bridge rail on Louisiana bridges. The F-Shape bridge rail is 32 inches in height and 13.25 inches wide at the base. Presently, for bridges that use this concrete F-Shape bridge rail, drainage is provided only at the ends of the bridge since there is no opening provided through the bridge rail. La DOTD has proposed the use of 6 inches high x 24 inches long open slots located 10 feet apart at the base of the rail to accommodate drainage through the railing. Details of the proposed bridge rail are provided as enclosure to this correspondence.

Crash Testing
The proposed La DOTD F-Shape Reinforced Concrete Barrier with Slotted Drain Holes (barrier) was analyzed at the test facilities at the TTI Proving Grounds Riverside Campus. The analysis was to evaluate the geometry and placement of the drainage slots on the barrier with respect to vehicle impact performance requirements for the NCHRP Report 350, TL-4 specifications.

The proposed drainage slot details were compared with other barriers systems utilizing similar type slots. This review consisted of comparisons with the Texas Department of Transportation (TXDOT) Single Slope Concrete Barrier (Wildlife Crossing) Precast SSCB (TXDOT Wildlife Crossing Barrier) and the Washington Pin & Loop Barrier System designed and successfully crash tested by TTI for the Washington State Department of Transportation (acceptance letter HSSD/B-206). The TTI researchers performed a similar review of the TXDOT Wildlife Crossing Barrier for TXDOT with respect to the size and potential interaction of these openings with respect to the small car and pickup truck for the NCHRP Report 350 crashworthiness criteria.

The potential for vehicular interaction with the barrier was evaluated with respect to the criteria in the AASHTO LRFD Bridge Design Specifications (AASHTO). Two figures are presented in the AASHTO that provide general guidelines for the crash performance of barrier that contain openings or penetrations. These figures provide guidelines for the preferred post set-back from the face of the railing elements and the preferred ratio of the rail contact widths to the overall height of the bridge rail system (see AASHTO Figures A13.1.1-2-Potential for Wheel, Bumper, or Hood Impact with a Post; and, A13.1.1-3-Post Setback Criteria). The potential for wheel interaction with the opening in the barrier was investigated. For the proposed barrier design, the post setback from the face of the rail elements was considered to be zero (0) inches. The maximum vertical clear opening distance between the bridge top of the bridge deck and the top of the opening is 7-5/8 inches. Based on this information and the information provided in AASHTO Figure A13.1.1-2, the clear opening height of 7-5/8 inches presents a low potential for vehicular interaction with the opening in the barrier during a vehicular crash.

The ratio in height of the contact length of the F-Shape Barrier to 32 inches total height of rail (i.e., rail contact width to height) is 0.762. Based on the proposed barrier geometry and the information provided in AASHTO Figure A13.1.1-3, the proposed barrier is considered marginal.

Findings
The analysis of the drainage slot used in the Washington State Department of Transportation Pin & Loop Barrier (WSDOT barrier) appeared to perform well in LS-DYNA impact simulations with both the small car and pickup truck. Although the WSDOT barrier did not meet the AASHTO Manual for Assessing Safety Hardware test specifications, the 9-inch high drainage slot specified used in the WSDOT barrier system did not adversely affect the performance of the crash vehicle. In addition, the potential for vehicle interaction with the drainage slot opening was considered low to marginal with respect to the criteria as provided in AASHTO Section 13 specifications. Based upon the researchers’ analysis, the F-Shape barrier with drainage slots is considered acceptable with respect to Report 350 TL-4 performance criteria.

Details including a side-by-side comparison between size openings of TXDOT Wildlife Crossing Barrier, WSDOT barrier, and LaDOTD F-Shape Barrier with drainage slots are provided as enclosure to this correspondence.

Therefore, the system as described in the request above and detailed in the enclosed drawings is acceptable for use on the NHS under the range of conditions tested, when such use is acceptable to a highway agency.

Please note the following standard provisions that apply to FHWA letters of acceptance:

 

Sincerely yours,

/* Signature of Michael S. Griffith */

Michael S. Griffith
Director, Office of Safety Technologies
Office of Safety

Enclosures

Page last modified on June 24, 2011